Ultrasonic distance transmitter (Large range)
Author:admin | Add Time: 01-11-10
Ultrasonic distance transmitter (Large range)
Type: WS-1101
Specifications:
- Working voltage: DC24V
- Detection methods: continuous detection 1hzs
- Detection range: 20 ~ 50 meters (with different sensors)
- Operating frequency: 20 ~ 40khz
- Blind Region: ≤ 600mm
- Accuracy: 0.3% F · S
- Data output: 4 ~ 20mA (default);
- 1 to 4 groups switch signal output
- RS485/232 serial data output
- (Based on user requirements can also customize a variety of different output modes)
- Operating temperature: 0 ~ 50 ℃ (default); -20 ~ 70 ℃ (custom)
- Working humidity: ≤ 80% RH, no condensation
- Storage temperature: -40 ~ 85 ℃
- Storage humidity: ≤ 70% RH, no condensation
- Protection class: Sensor IP68, IP65 meter
Features:
- Non-contact measurement, environmental protection, safety, convenience.
- Split design, elegant appearance, convenient TO installation.
- In different environments from the accuracy of online calibration, starting and ending point range, the output module, window lock values can be set by software. Can be used in a variety of complex environmental conditions, To meet the user to install on-site requirements.
- With a wide range of temperature compensation and original ERD interference intelligent recognition system, so that stable measurement precision.
- Added value / difference measurement mode selection, ranging can also be measured position.
- Optional host computer or PC software, networking, a host can be 2 to 128 extensions on the network inspection (optional)
- With full scale overflow tips, and beginning and end of any full-scale digital translation function. With "echo identification" function and "the slope of the" digital filtering, for different operating conditions.
- With 4mA, 20mA digital fine-tuning features that make on-site installation and maintenance is very convenient and fast! With 1 to 15 transmit power selection, can be adjusted according to site conditions;
- With 10 seconds / second ~ 100 times / sec test cycle set to fit for the measurement of fast and slow moving target capture.